THE BEST SIDE OF DP50RB

The best Side of Dp50rb

The best Side of Dp50rb

Blog Article

The consumer isn't permitted to open the handles and panel on the method, neither Notice: product disassemble is authorized. To ensure the technique effectiveness and basic safety, only Mindray engineers or engineers approved by Mindray can carry out maintenance.

iZoom™ permits precise viewing of graphic from distance iWorks™ Protocol allows standardize workflow and decrease exam occasions

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Be aware: Make sure that you could potentially pull out and force to the IO board sockets vertically when pulling out and assembling the IO board assembly on the situation of the manage. Eliminate panhead screws with washers M3X6 (four) used to secure the IO board, after which you can you could take out the IO board. Web page 116 Get rid of panhead screws with washers (two M3X6) which happen to be fixed on the key device, just take out the upper baffle after which pull out two cables connecting the primary board to the power module assembly.

Site one hundred forty five Clear user interface Instruments: dry delicate cloth, moderate soapy drinking water  System:  Use dry comfortable fabric to wash the surface with the technique. Should the program is filthy, moisten the tender cloth with mild soapy water and wipe off any stains. Use dry gentle fabric to get rid of any moisture and permit all hard surfaces to totally air-dry. Web page 146: Clean up The Peripherals

Never use any cables apart from the cables presented With all the product by Mindray. three. Utilize the cable presented with This method to connect the printer. Other cables may perhaps bring about electrical shock. Webpage fifteen: Mechanical Basic safety

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Check Stage: Do adjustments as the way in which in tests the utmost depth. Report the distance by 20mm Every single segment around the longitudinal targets line utilizing the measurement caliper; Pick out the value with the best mistake (to 20mm), estimate the precision using the components below The measurement caliper should be positioned for the upper edge of the concentrate on, Notice:... Web page 79 Transverse geometric positioning precision  Check Move: Go over the scan area on the phantom with h2o or few gel, Carefully Get in touch with the probe Using the scan floor Regulate the depth, generating the transverse targets to be shown in the picture. Alter the main focus point to generally be posited beside the transverse targets (the common is just not apparent) Change parameters like gain, TGC, earning Every transverse targets to become Obviously shown. Web page 80 5.five.2.four Blackout Location Check Phase: Protect the scan area in the phantom with h2o or pair gel, gently Make contact with the probe With all the scan area Adjust the depth at a reduced price, and set the focus at the nearest destination to the scan surface area. Lessen the value of parameters like AP, Achieve till the background sounds just can be witnessed. Web site eighty one: Application Enhance And Routine maintenance

Notice: Just before uploading the log, make certain the ultrasound method continues to be connected to network, normally, the process may alert “could not hook up with server” The server (smtp.

Soon after replacing the CPU module, essential file should be generated once again in accordance with the new MAC handle and written into HDD of the equipment. Or else, the configuration function of your products will probably be misplaced. After eradicating the CPU module, Clear away panhead screws with washers (12 M3X6) fastened on the principle unit box, you normally takes off the board. Page 118 Figure eight-29 Disassemble the User interface Assembly (1) Maintain the upper edge of control panel Dp50rb login assembly, and open up the user interface. Determine eight-thirty Disassemble the User interface Assembly (2) Immediately after removing a single countersunk head self-tapping screw PT3X10 preset on the user interface and take out the plug on the keyboard and the most crucial device connecting cables, you could potentially take out the user interface assembly.

If you prevent the scanning and also the image capture, you must electric power off the technique and disconnect the process with the AC ability offer, then pull out AC electric power cables. Web page 109: Battery Connecting Board

This handbook might referring to information and facts safeguarded by copyright or patents and doesn't Express any license underneath the patent rights or copyright of Mindray, or of Some others. Website page 9: Statement

Slash off cable ties connecting the leading device within the Exhibit by diagonal cutting pliers, and then pull out the corresponding cable plugs.

Content Approach Check out the battery periodically : a) Check out if battery might be charged Usually when energy-on: That the current potential is 100% or potential boosts immediately after a short time implies the battery may be billed Usually.